G-418 Sulfate (G418),Geneticin-常用生化试剂-试剂-生物在线
上海联硕生物科技有限公司
G-418 Sulfate (G418),Geneticin

G-418 Sulfate (G418),Geneticin

商家询价

产品名称: G-418 Sulfate (G418),Geneticin

英文名称:

产品编号: 11811-023

产品价格: 0

产品产地: USA

品牌商标: Gibco

更新时间: null

使用范围: null

上海联硕生物科技有限公司
  • 联系人 : 小徐
  • 地址 : 上海市嘉松中路3555号A1栋
  • 邮编 : 201801
  • 所在区域 : 上海
  • 电话 : 166****7207 点击查看
  • 传真 : 点击查看
  • 邮箱 : lianshuo@vip.126.com

 Ultra Pure Grade

C20H40N4O10 2H2SO4  MW: 692.7

Activity (U/mg) ....................................> 710

Moisture (LOD) () ................................ < 10.0

Storage at C

 

,货号11811-023,技术参数如下:
Shipping Conditions

GENETICIN is shipped at ambient temperature.
Storage Conditions
GENETICIN should be stored at room temperature, 15 to 30°C. GENETICIN is soluble in water and should be stored at 2 to 8°C as a solution.
Background
GENETICIN is an aminoglycoside related to Gentamicin and is used as a selective agent in molecular genetics experiments. It is toxic to both prokaryotic and eukaryotic cells. The resistance genes are dominant and are located on both Transposons Tn601 (903) and Tn5. The gene on Tn5 is referred to as a aminoglycoside phosphotransferase 3 (I) or APH(3)I.The genes are bacterial in derivation but they can be expressed in eukaryotic cells. Efficient expression is achieved when the neo DNA sequence is linked to eukaryotic DNA sequences that permit transcription and processing of the Neo coding sequence into mRNA. Introduction of either of these genes into cells can confer resistance to GENETICIN, enabling the cells to grow in media containing GENETICIN. 
Description
GENETICIN is also known as Antibiotic G-418 Sulfate. GENETICIN is supplied
as a white powder. The amount of GENETICIN required to be present in culture media to select for resistant cells varies with a number of factors including cell type. Good laboratory practice requires that the optimal concentration of GENETICIN required to maintain and select cells must be determined for each set of growth conditions. Invitrogen recommends that whenever experimental conditions are altered (including use of GENETICIN from a different lot), the optimal concentration of the product be re-evaluated.
Quality Control
Absorbance - Visible range: At a concentration of 100 mg/mL in water, GENETICIN gives a clear colorless solution. The absorbance of this solution at 400 nm is less than 0.075 O.D.
Absorbance - Ultraviolet range: At a concentration of 1 mg/mL in water, the absorbance at 280 nm is less than 0.015 O.D.